Turi umwe mubatanze ubuhanga bwa FA One-stop batanga mubushinwa.Ibicuruzwa byacu byingenzi birimo moteri ya servo, garebox yumubumbe, inverter na PLC, HMI. Ibicuruzwa birimo Panasonic, Mitsubishi, Yaskawa, Delta, TECO, Sanyo Denki, Scheider, Siemens , Omron nibindi.; Igihe cyo kohereza: Mu minsi 3-5 y'akazi nyuma yo kubona ubwishyu. Inzira yo kwishyura: T / T, L / C, PayPal, West Union, Alipay, Wechat nibindi
Ibisobanuro
TeSys GV yamashanyarazi yamashanyarazi, inkingi 3 (3P), 1.6A / 690V, kubisabwa ibyiciro 3 byimodoka 0.37-0.55kW@400V. Itanga ubushyuhe-magnetiki burinda hamwe nubushyuhe bwa 1-1.6A, kugendagenda kuri magneti kuri 13xIn, ubushobozi bwo kumena cyane Icu 100kA @ 400V. Kwihuza kumurongo wimpeshyi. Gutangira-guhagarika kugenzura ukoresheje buto-buto yemerewe 100 000 cycle AC-3. Ibipimo byinshi byemejwe (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium yujuje (RoHS / REACh).
Ibisobanuro
Urwego | TeSys Deca |
---|---|
Izina ryibicuruzwa | TeSys GV2 TeSys Deca |
ibicuruzwa cyangwa ubwoko bwibigize | Kumena moteri |
Igikoresho izina rigufi | GV2ME |
Porogaramu | Kurinda moteri |
Ikoranabuhanga ryurugendo | Ubushuhe-rukuruzi |
inkingi ibisobanuro | 3P |
---|---|
Ubwoko bw'urusobe | AC |
Icyiciro cyo gukoresha | Icyiciro A gihuye na IEC 60947-2 AC-3 ihuye na IEC 60947-4-1 AC-3e ihuye na IEC 60947-4-1 |
Umuyoboro | 50/60 Hz ihuye na IEC 60947-4-1 |
Uburyo bwo gukosora | 35 mm ihuza DIN ya gari ya moshi: yaciwe Ikibaho: cyasunitswe (hamwe na plaque ya adapt) |
Imbaraga za moteri kW | 0.37 kW kuri 400/415 V AC 50/60 Hz 0.55 kW kuri 400/415 V AC 50/60 Hz 0.37 kW kuri 500 V AC 50/60 Hz 0.55 kW kuri 500 V AC 50/60 Hz 0,75 kW kuri 500 V AC 50/60 Hz |
Ubushobozi bwo kumena | 100 kA Icu kuri 230/240 V AC 50/60 Hz ihuye na IEC 60947-2 100 kA Icu kuri 400/415 V AC 50/60 Hz ihuye na IEC 60947-2 100 kA Icu kuri 440 V AC 50/60 Hz ihuye na IEC 60947-2 100 kA Icu kuri 500 V AC 50/60 Hz ihuye na IEC 60947-2 100 kA Icu kuri 690 V AC 50/60 Hz ihuye na IEC 60947-2 |
[Ics] amanota ya serivise yagabanutse ubushobozi buke bwo kumeneka | 100% kuri 230/240 V AC 50/60 Hz ihuye na IEC 60947-2 100% kuri 400/415 V AC 50/60 Hz ihuye na IEC 60947-2 100% kuri 440 V AC 50/60 Hz ihuye na IEC 60947-2 100% kuri 500 V AC 50/60 Hz ihuye na IEC 60947-2 100% kuri 690 V AC 50/60 Hz ihuye na IEC 60947-2 |
Ubwoko bwo kugenzura | Kanda buto |
Ikigereranyo cyagenwe | 1.6 A. |
Urwego rwo kurinda ubushyuhe | 1… 1.6 Guhuza na IEC 60947-4-1 |
Inzira ya rukuruzi | 22.5 A. |
[Ith] isanzwe yubusa yubushyuhe bwumuriro | 1.6 Guhuza na IEC 60947-4-1 |
[Ue] yagereranije voltage ikora | 690 V AC 50/60 Hz ihuye na IEC 60947-2 |
[Ui] yagereranije voltage voltage | 690 V AC 50/60 Hz ihuye na IEC 60947-2 |
[Uimp] igipimo cya impulse cyihanganira voltage | 6 kV ihuye na IEC 60947-2 |
Icyiciro cyo kunanirwa | Yego guhuza na IEC 60947-4-1 |
Birakwiriye kwigunga | Yego guhuza na IEC 60947-1 § 7-1-6 |
Gukwirakwiza ingufu kuri pole | 2.5 W. |
Kuramba kwa mashini | Inzinguzingo 100000 |
Kuramba kw'amashanyarazi | Inzinguzingo 100000 kuri AC-3 kuri 415 V Muri Inzinguzingo 100000 kuri AC-3e kuri 415 V Muri |
Inshingano yagenwe | Gukomeza guhuza na IEC 60947-4-1 |
Ubugari | 45 mm |
Uburebure | Mm 101 |
Ubujyakuzimu | 78.5 mm |
uburemere | 0,28 kg |
Ibara | Icyatsi cyijimye |
Ibipimo | EN / IEC 60947-2 EN / IEC 60947-4-1 |
---|---|
Icyemezo cyibicuruzwa | CCC UL CSA EAC ATEX LROS (Lloyds igitabo cyo kohereza) BV RINA DNV-GL UKCA |
IK urwego rwo kurinda | IK04 |
Urwego rwa IP rwo kurinda | IP20 ihuye na IEC 60529 |
Ikirere cyihanganira ikirere | Guhuza na IACS E10 |
Ubushyuhe bwo mu kirere bubitse | -40… 80 ° C. |
Kurwanya umuriro | 960 ° C ihuye na IEC 60695-2-11 |
Ubushyuhe bwikirere bwikirere kugirango bukore | -20… 60 ° C. |
Gukomera kwa mashini | Shocks: 30 Gn kuri 11 ms Kunyeganyega: 5 Gn, 5 ... 150 Hz |
Gukorera hejuru | 2000 m |